Issue: WARNING: RPA fan failure detected. Contact EMC Customer Service
Resolution:
1. Set the RPA Cluster to Maintenance Mode
> login to the Cluster using admin credential using tool like putty (default admin/admin)
> enter the cmd for enter into maintenance mode
Resolution:
1. Set the RPA Cluster to Maintenance Mode
> login to the Cluster using admin credential using tool like putty (default admin/admin)
> enter the cmd for enter into maintenance mode
RPACluster>
start_maintenance_mode
Enter the kind of upgrade.
1) major_upgrade
2) minor_upgrade
3) rpa_addition
4) rpa_replacement
5) rpse_conversion
6) system_modification
7) user_initiated
8) connect_cluster
Select: 6
Enter cluster name
RPACluster
Switched to maintenance mode
successfully.
2. Reboot the Respective RPA node (in this case i am rebooting RPA Node 5)
> login to the RPA Node using boxmgmt credential (Default Credential: boxmgmt/boxmgmt)
** Main Menu **
[1] Installation
[2] Setup
[3] Diagnostics
[4] Cluster operations
[5] Shutdown / Reboot operations
[Q] Quit
RPACluster RPA 5: 5
** Shutdown / Reboot operations
**
[1] Reboot RPA
[2] Shutdown RPA
[M] Main Menu
[B] Back
[Q] Quit
RPACluster RPA 5: 1
Reboot in progress, please wait.
3. After reboot, check the error message is gone.
If note please follow the below steps
- Shut down the RPA
- Remove the power cord from the power supply unit of the affected RPA (disconnect the cord from the PSU or unplug it from the wall)
- Wait for 10 seconds and reinsert the power cord and boot the RPA.
- Monitor the environment (RPA and site power).
4. finally release the cluster from Maintenance Mode
RPACluster > finish_maintenance_mode
Enter cluster name, or press 'ENTER' for all clusters
RPACluster
Maintenance mode finished successfully.